• Decrease font size
  • Reset font size to default
  • Increase font size

EEMS Ltd

For all your Portable Appliance Testing needs:

Testing Services

Training Courses

Landlords fixed installation reports

EEMS Ltd provide services to Industrial, Commercial, Public and Privates sectors.

Subscribe to our one day Portable Appliance Testing training course at our training facility or on your site.

 

Home arrow Inspection and Testing
Periodic Inspection and Testing (Fixed Installations)

EEMS Ltd are able to supply inspection and testing services for fixed installations to BS7671. EEMS personnel carrying out this testing are qualified to both City and Guilds 2381 and 2391.

All inspection and testing services are accompanied with a comprehensive report. In the case of a Periodic Inspection an IEE certificate will be issued.

Testing of installations is required to be undertaken at specific intervals dependant on the type of premises.

Testing is required as systems will deteriorate over time depandant on a number of factors which include environment, temperature, loading, wear and tear, damage and corrosive elements. 

We offer three levels of service for our client base:

Bronze Service     (Visual Electrical Inspection)

Includes a visual inspection of:

Main equipotential bonding                                                           

Supplementary bonding

Inspection for physical damage

Deterioration or signs of overheating of equipment

Missing parts and covers

Mechanical security of fittings

followed by a test at each ring/radial socket for correct voltage and polarity.

Note that no interuption of supply is required for this service.

A full report is produced detailing the degree of testing carried out and the results and details of any observations. 

 

Silver Service    (Routine Electrical Inspection)

Includes all elements of the bronze service with the addition of:

A minimum of 10% sampling of joint, terminations at lighting points and socket outlets

Functional test on all switchgear

Test of all circuit breakers (excluding current characteristics)

RCD disconnect testing function

Each ring/radial socket will also be tested to ensure earth loop impedance falls into passbands for protective devices

Note that during this service there will be an interuption to the supply. 

 

Gold Service    (Periodic Inspection  to BS7671)

This inspection is a comprehensive test and inspection procedure defined by the IEE in regulations BS7671.

The scope of the testing required to be carried out imust be agreed with the client before any inspection is carried out as not all parts may be accessible or convenient to be switched off and an agreed sample size may have to be taken. EEMS Ltd will work closely with its client base to help to arrive at an acceptable testing plan.

On completion of the Inspection and Test works a report will be provided which details the conditions of the installation, the results of all the tests carried out listing any faults recorded and recommendations for any remedial work. 

 


 

 

                
 

 

 

Who's Online

We have 3 guests online